Internal audit on Medical Device QMS – ISO 485:

Premium Practice Questions

How does ISO 13485:2016 address the concept of a “risk-based approach” beyond the explicit requirements of ISO 14971, and how should an internal audit assess the effective integration of this broader risk-based thinking throughout the QMS?

ISO 13485:2016 emphasizes a risk-based approach not only in product realization (addressed by ISO 14971) but also throughout the entire QMS, including processes like document control, training, and supplier management. This means organizations must identify, assess, and control risks associated with these processes to ensure product safety and regulatory compliance. An internal audit should evaluate how the organization has integrated risk-based thinking into these areas. This includes reviewing documented procedures to ensure risk assessments are conducted, evaluating records to verify that identified risks are appropriately controlled, and interviewing personnel to assess their understanding of risk-based decision-making. Auditors should look for evidence that the organization proactively identifies potential risks and implements controls to mitigate them, rather than simply reacting to problems after they occur. Clause 4.1.2 of ISO 13485:2016 specifically requires the organization to apply a risk-based approach to the QMS processes.

Considering the documentation requirements of ISO 13485:2016, how should an internal audit differentiate between necessary documentation for compliance and documentation that adds limited value, potentially hindering efficiency and maintainability of the QMS?

ISO 13485:2016 requires documented procedures and records to demonstrate conformity to the QMS and regulatory requirements. However, excessive or poorly managed documentation can create inefficiencies. An internal audit should assess whether documentation is necessary and adds value. This involves evaluating if the documentation directly supports product safety, regulatory compliance, or process effectiveness. Auditors should review the documentation hierarchy, ensuring that documents are clear, concise, and easily accessible. They should also assess the document control process to verify that documents are regularly reviewed and updated. Furthermore, the audit should consider the impact of documentation on employee workload and process efficiency. If documentation is found to be redundant, outdated, or overly complex, the audit should recommend streamlining or eliminating it. The goal is to maintain a lean and effective QMS that meets regulatory requirements without unnecessary burden. Clause 4.2 of ISO 13485:2016 outlines the general requirements for documentation control.

How can an internal audit effectively assess the “suitability” and “effectiveness” of a medical device manufacturer’s quality policy, as mandated by ISO 13485:2016, beyond simply verifying its existence and communication?

Assessing the suitability and effectiveness of a quality policy requires more than just confirming its existence and communication. An internal audit should evaluate whether the policy aligns with the organization’s strategic objectives, regulatory requirements, and the needs of its customers. This involves reviewing the policy’s content to ensure it addresses key aspects of product safety, quality, and continuous improvement. Auditors should also assess how the policy is implemented throughout the organization. This includes interviewing employees to gauge their understanding of the policy and observing how it influences their daily activities. Furthermore, the audit should examine objective evidence, such as quality metrics and performance indicators, to determine if the policy is contributing to improved quality outcomes. If the audit reveals that the policy is not effectively driving quality improvements or is not well-understood by employees, recommendations should be made to revise and strengthen it. Clause 5.3 of ISO 13485:2016 details the requirements for the quality policy.

In the context of ISO 14971:2019, how should an internal audit verify that a medical device manufacturer’s risk management process adequately addresses “benefit-risk” determinations, particularly for devices with innovative features or intended for high-risk patient populations?

ISO 14971:2019 emphasizes the importance of benefit-risk analysis in medical device risk management. An internal audit should verify that the manufacturer’s risk management process adequately addresses this aspect, especially for innovative devices or those intended for high-risk patients. This involves reviewing the risk management plan to ensure it includes a defined process for evaluating and documenting benefit-risk determinations. Auditors should examine risk assessments to confirm that both potential hazards and clinical benefits are considered. They should also assess the rationale behind benefit-risk decisions, ensuring that they are based on sound scientific evidence and ethical considerations. Furthermore, the audit should evaluate how benefit-risk information is communicated to users and regulatory authorities. If the audit reveals deficiencies in the benefit-risk assessment process, recommendations should be made to strengthen it, potentially involving clinical experts or patient representatives. ISO 14971:2019 provides detailed guidance on risk management, including benefit-risk analysis.

How should an internal audit assess the effectiveness of design verification and validation activities, as required by ISO 13485:2016, in demonstrating that a medical device consistently meets its intended use and user needs, particularly when dealing with complex software-driven devices?

Design verification and validation are critical for ensuring that a medical device meets its intended use and user needs. An internal audit should assess the effectiveness of these activities by reviewing the design and development plan to ensure it includes clearly defined verification and validation criteria. Auditors should examine verification reports to confirm that the device meets specified design inputs and validation reports to confirm that it meets user needs under simulated or actual use conditions. For complex software-driven devices, the audit should pay particular attention to software validation activities, including testing for usability, security, and interoperability. Furthermore, the audit should evaluate the traceability between design inputs, verification activities, and validation results. If the audit reveals deficiencies in the verification or validation process, recommendations should be made to improve testing methodologies, address identified gaps, and ensure that the device consistently meets its intended use. Clause 7.3.6 and 7.3.7 of ISO 13485:2016 detail the requirements for design verification and validation.

Considering the requirements for supplier and purchasing controls in ISO 13485:2016, how can an internal audit determine if a medical device manufacturer’s supplier evaluation process adequately addresses the risk of counterfeit or substandard materials entering the supply chain, especially for critical components?

ISO 13485:2016 requires manufacturers to control their suppliers to ensure that purchased products and services conform to specified requirements. An internal audit should assess whether the supplier evaluation process adequately addresses the risk of counterfeit or substandard materials entering the supply chain, particularly for critical components. This involves reviewing the supplier selection criteria to ensure they include measures to assess the supplier’s ability to detect and prevent counterfeit materials. Auditors should examine supplier audit reports to confirm that suppliers are regularly assessed for compliance with quality standards and anti-counterfeiting measures. They should also evaluate the manufacturer’s process for verifying the authenticity of purchased materials, such as through testing or inspection. Furthermore, the audit should assess the manufacturer’s response plan in the event that counterfeit materials are detected. If the audit reveals deficiencies in the supplier evaluation process, recommendations should be made to strengthen controls and mitigate the risk of counterfeit materials. Clause 7.4 of ISO 13485:2016 outlines the requirements for purchasing controls.

How should an internal audit evaluate the effectiveness of a medical device manufacturer’s process validation activities, as required by ISO 13485:2016, in ensuring that production processes consistently deliver products meeting predetermined specifications, particularly for processes involving complex sterilization or aseptic techniques?

Process validation is crucial for ensuring that production processes consistently deliver products meeting predetermined specifications. An internal audit should evaluate the effectiveness of process validation activities by reviewing the validation plan to ensure it includes clearly defined acceptance criteria and testing methodologies. Auditors should examine validation reports to confirm that the process consistently meets the acceptance criteria under various operating conditions. For processes involving complex sterilization or aseptic techniques, the audit should pay particular attention to the validation of these processes, including microbiological testing and environmental monitoring. Furthermore, the audit should evaluate the process for revalidation following changes to the process or equipment. If the audit reveals deficiencies in the validation process, recommendations should be made to improve testing methodologies, address identified gaps, and ensure that the process consistently delivers products meeting specifications. Clause 7.5.6 of ISO 13485:2016 details the requirements for validation of processes.

How should a medical device manufacturer demonstrate and document the effectiveness of its training programs, and what specific metrics can be used to evaluate the impact of training on employee competence and product quality, referencing ISO 13485:2016 clause 6.2.2?

Demonstrating and documenting the effectiveness of training programs involves a multi-faceted approach. ISO 13485:2016 clause 6.2.2 emphasizes the need for personnel to be competent based on appropriate education, training, skills, and experience. To measure training effectiveness, manufacturers should define clear objectives for each training program and establish metrics to assess whether these objectives are met. Metrics can include: post-training assessments (e.g., written tests, practical demonstrations) to evaluate knowledge and skill acquisition; on-the-job performance evaluations to observe the application of learned skills in real-world scenarios; defect rates and error reduction related to trained tasks; employee feedback surveys to gauge understanding and confidence; and audit findings related to trained processes. Documentation should include training records, assessment results, performance evaluations, and any corrective actions taken to improve training programs. Regular review and analysis of these metrics are crucial for continuous improvement of the training process, ensuring that employees maintain the necessary competence to consistently meet product quality and regulatory requirements. This aligns with the broader QMS objectives of ISO 13485.

What are the key elements of a robust document control system for a medical device QMS, and how does ISO 13485:2016 ensure that documents are properly created, reviewed, approved, and maintained throughout their lifecycle, referencing clauses 4.2.3 and 4.2.4?

A robust document control system for a medical device QMS encompasses several critical elements. These include: a defined process for document creation, review, and approval; a system for version control to track changes and ensure the use of current documents; controlled access to documents to prevent unauthorized modifications; a mechanism for document distribution and retrieval; and a process for obsolete document removal. ISO 13485:2016 clauses 4.2.3 and 4.2.4 outline specific requirements for document control. Clause 4.2.3 mandates that documents be reviewed and approved for adequacy prior to issue, and that changes are reviewed and approved by designated personnel. Clause 4.2.4 focuses on record control, requiring that records be established and maintained to provide evidence of conformity to requirements and the effective operation of the QMS. The standard emphasizes the importance of maintaining document integrity, preventing unintended use of obsolete documents, and ensuring that documents are legible, readily identifiable, and retrievable. Electronic document management systems (EDMS) can be used to streamline these processes, but must also comply with the standard’s requirements for security, data integrity, and audit trails.

How does a medical device manufacturer establish and maintain a post-market surveillance system that effectively collects, analyzes, and reports adverse events and incidents, and what are the key regulatory requirements for vigilance reporting to authorities like the FDA or EMA, referencing ISO 13485:2016 clause 8.2.1 and relevant regulatory guidelines?

Establishing and maintaining an effective post-market surveillance system involves several key steps. First, the manufacturer must define data collection methods, including sources such as customer complaints, service reports, field alerts, and regulatory databases. ISO 13485:2016 clause 8.2.1 requires the organization to monitor information relating to whether the organization has met customer requirements. Next, the collected data must be analyzed to identify trends, patterns, and potential safety issues. This analysis should include risk assessment to determine the severity and probability of harm associated with identified issues. Based on the analysis, the manufacturer must implement corrective and preventive actions (CAPA) to address the root causes of adverse events. Regulatory requirements for vigilance reporting vary by region. In the US, the FDA requires manufacturers to submit Medical Device Reports (MDRs) for certain adverse events. In Europe, the Medical Device Regulation (MDR) mandates reporting of serious incidents to competent authorities. These reports must include detailed information about the device, the event, and any corrective actions taken. Compliance with these regulatory requirements is crucial to ensure patient safety and maintain market access.

What are the essential steps a medical device manufacturer should take to prepare for an external audit by a regulatory body like the FDA or EMA, and how can they ensure compliance with applicable regulations and standards during the audit process, referencing ISO 13485:2016 clause 4.1.4 and relevant regulatory guidelines?

Preparing for an external audit requires a systematic approach. First, the manufacturer should conduct a thorough internal audit to identify any gaps in their QMS. This internal audit should cover all aspects of the QMS, including document control, CAPA, risk management, and production processes. ISO 13485:2016 clause 4.1.4 requires the organization to plan, establish, and maintain a documented quality management system. Next, the manufacturer should review all relevant regulations and standards, such as the FDA’s Quality System Regulation (21 CFR Part 820) or the EU’s Medical Device Regulation (MDR). They should ensure that their QMS documentation is up-to-date and reflects current requirements. During the audit, the manufacturer should cooperate fully with the auditors, providing them with access to all relevant documents and records. They should also ensure that key personnel are available to answer questions and provide explanations. Any findings or observations made by the auditors should be addressed promptly and effectively. A well-prepared and executed audit response can demonstrate a commitment to quality and compliance, fostering a positive relationship with regulatory bodies.

How can a medical device manufacturer effectively utilize key performance indicators (KPIs) to monitor and improve the performance of their QMS, and what are some examples of relevant KPIs that can be used to track quality, efficiency, and customer satisfaction, referencing ISO 13485:2016 clause 8.4 and related guidance documents?

Effectively utilizing KPIs involves several steps. First, the manufacturer must identify the critical processes and areas that have the greatest impact on product quality, patient safety, and business performance. ISO 13485:2016 clause 8.4 requires the organization to determine, collect and analyze appropriate data to demonstrate the suitability and effectiveness of the quality management system. Next, they should define specific, measurable, achievable, relevant, and time-bound (SMART) KPIs for each identified area. Examples of relevant KPIs include: defect rates, CAPA completion rates, customer complaint resolution times, on-time delivery performance, and supplier performance ratings. The manufacturer should establish a system for collecting and analyzing KPI data on a regular basis. This data should be used to identify trends, patterns, and areas for improvement. The results of the KPI analysis should be communicated to relevant stakeholders, and corrective actions should be implemented to address any identified issues. Regular review and adjustment of KPIs are essential to ensure that they remain relevant and effective in driving continuous improvement.

What are the key considerations for managing changes to a medical device QMS, and how can a manufacturer ensure that changes are properly assessed, documented, communicated, and implemented to maintain compliance and product quality, referencing ISO 13485:2016 clause 4.2.5 and related guidance?

Managing changes to a medical device QMS requires a structured approach. First, the manufacturer must establish a change control process that defines the steps for initiating, evaluating, approving, and implementing changes. ISO 13485:2016 clause 4.2.5 requires the organization to control changes to documents. Next, any proposed change should be assessed for its potential impact on product quality, patient safety, regulatory compliance, and other aspects of the QMS. This assessment should involve relevant stakeholders, such as engineering, manufacturing, quality assurance, and regulatory affairs. All changes must be documented in detail, including the rationale for the change, the impact assessment, the implementation plan, and the verification and validation results. The change should be communicated to all affected personnel, and training should be provided as necessary. Post-implementation monitoring is crucial to ensure that the change has the desired effect and does not introduce any unintended consequences.

How can a medical device manufacturer foster a culture of ethics and compliance within their organization, and what mechanisms can be implemented to encourage ethical behavior, prevent misconduct, and ensure compliance with applicable laws and regulations, referencing relevant industry codes of conduct and regulatory guidelines?

Fostering a culture of ethics and compliance requires a commitment from top management and a comprehensive approach. First, the manufacturer should develop a code of conduct that outlines the ethical principles and standards of behavior expected of all employees. This code should be communicated to all employees, and training should be provided to ensure that they understand their obligations. Next, the manufacturer should establish mechanisms for reporting suspected misconduct, such as a whistleblower hotline or an anonymous reporting system. These mechanisms should be confidential and protect whistleblowers from retaliation. Regular audits and monitoring should be conducted to detect and prevent misconduct. Disciplinary actions should be taken against employees who violate the code of conduct or engage in unethical behavior. The manufacturer should also promote ethical decision-making through training, communication, and leadership by example. Compliance with applicable laws and regulations should be a core value of the organization, and all employees should be held accountable for their actions.

By CertMedbry Exam Team

Get More Practice Questions

Input your email below to receive Part Two immediately

Start Set 2 With Google Login

Gain An Unfair Advantage

Prepare your medical exam with the best study tool in the market

Support All Devices

Take all practice questions anytime, anywhere. CertMedbry support all mobile, laptop and eletronic devices.

Invest In The Best Tool

All practice questions and study notes are carefully crafted to help candidates like you to pass the insurance exam with ease.

Study Mindmap

It’s easy to get confused and lost in your studies. At CertMedbry, we provide you with a study mindmap to help you develop a holistic understanding of how to study, improving your efficiency and effectiveness.

Invest In The Best Tool

All practice questions and study notes are carefully crafted to help candidates like you to pass the medical exam with ease.

Key Video Study Notes by Certmedbry

Certmedbry condenses critical medical exam content into concise, audio-narrated study notes. Our FAQ-style format highlights essential concepts while the voiceover feature lets you study hands-free during commutes, exercise, or downtime. Perfect for busy medical professionals, these portable notes transform unproductive time into effective study sessions. Learn with your eyes closed or while multitasking, ensuring you master key exam material regardless of your schedule. Maximize your preparation efficiency with Certmedbry’s specialized audio study solution.

Get CertMedbry Premium Access

Invest In Yourself For Less Than The Price Of A Coffee Today

Pass Internal audit on Medical Device QMS – ISO 485: With A Peace Of Mind

Certmedbry Premium Access (30 Days Access)

Number Of Practice Questions: 2800

Unlimited Access
Support All Devices
One Year Success Guarantee

Just USD6.6 Per Day
Last Updated: 09 November 2025

One time payment, no recurring fees

Certmedbry Premium Access (60 Days Access)

Number Of Practice Questions: 2800

Unlimited Access
Support All Devices
One Year Success Guarantee

Just USD4.1 Per Day
Last Updated: 09 November 2025

One time payment, no recurring fees

Certmedbry Premium Access (90 Days Access)

Number Of Practice Questions: 2800

Unlimited Access
Support All Devices
One Year Success Guarantee

Just USD3.3 Per Day
Last Updated: 09 November 2025

One time payment, no recurring fees

Certmedbry Premium Access (180 Days Access)

Number Of Practice Questions: 2800

Unlimited Access
Support All Devices
One Year Success Guarantee

Just USD1.9 Per Day
Last Updated: 09 November 2025

One time payment, no recurring fees

Why CertMedbry

Our past candidates loves us. Let’s see how they think about our service

John
JohnVerified Buyer
CertMedbry was a lifesaver for my USMLE Step 1 prep. The practice questions were on point, and the explanations helped me understand where I was going wrong. Highly recommend this for anyone gearing up for the exam!
Emily R.
Emily R.Verified Buyer
CertMedbry’s COMLEX Level 1 prep helped me stay organized and focused. The detailed feedback from the quizzes really highlighted where I needed to improve. I’m glad I chose them for my study plan.
David H.
David H.Verified Buyer
Preparing for the PANCE was a daunting task, but CertMedbry’s study resources made it manageable. The practice exams were spot-on, and I felt ready when the test day came.
Sophia G.
Sophia G.Verified Buyer
CertMedbry’s COMLEX Level 2 study guides were incredibly helpful. I loved how detailed the explanations were, and the practice questions really made a difference for me.
Brian K.
Brian K.Verified Buyer
The NCLEX-PN is no joke, but CertMedbry made studying manageable. Their quizzes really pushed me to think critically, and I felt prepared for the big day.
Olivia C.
Olivia C.Verified Buyer
CertMedbry’s content for the MPJE was top-notch. I appreciated the way they broke down tricky concepts, and the practice tests were an amazing tool for my success.
Daniel E.
Daniel E.Verified Buyer
Preparing for the COMLEX Level 1 felt overwhelming until I started using CertMedbry. Their review material was comprehensive, and it gave me the confidence I needed to pass.
Sarah M.
Sarah M.Verified Buyer
I used CertMedbry for my ADC Exam prep, and it made all the difference. The material was easy to follow, and I felt way more confident walking into the test. Totally worth it!
Michael S.
Michael S.Verified Buyer
I was looking for reliable practice tests for the NBDHE Exam, and CertMedbry delivered. Their platform made studying less overwhelming, and I passed without any issues. Definitely recommend!
Rachel W.
Rachel W.Verified Buyer
CertMedbry was exactly what I needed for my ARRT exam prep. Their material was super relevant, and I felt much more confident walking into the test. Definitely a solid investment.
Mark A.
Mark A.Verified Buyer
CertMedbry helped me pass my USMLE Step 2 with flying colors. The questions felt just like the real thing, and the explanations were so helpful. I couldn’t have done it without them!
Megan B.
Megan B.Verified Buyer
CertMedbry’s COMLEX Level 2 prep was awesome. The explanations were thorough and easy to understand, and the test simulations gave me a real sense of what to expect on exam day.
Ethan V.
Ethan V.Verified Buyer
The USMLE Step 3 was intimidating, but CertMedbry’s platform made it so much easier to prepare. The way they structured their material really worked for me.
Jessica N.
Jessica N.Verified Buyer
CertMedbry’s review for the Certified Pediatric Nurse exam was incredibly thorough. It helped me focus on key areas and ultimately pass with ease. I highly recommend it!
James P.
James P.Verified Buyer
Studying for the NCLEX-RN was stressful, but CertMedbry took a lot of that anxiety away. Their content was clear, and the practice tests were super helpful. I passed on my first try!
Anna L.
Anna L.Verified Buyer
CertMedbry’s NCLEX-PN review was a game changer for me. The practice questions were challenging but fair, and I felt fully prepared when exam day came around. Thanks, CertMedbry!
Chris T.
Chris T.Verified Buyer
I used CertMedbry for the MPJE, and it helped me get the result I wanted. Their resources were clear and to the point, which made reviewing the material so much easier.
Laura J.
Laura J.Verified Buyer
I used CertMedbry to prep for the American Board of Pediatrics exam, and it was a huge help. Their detailed questions and mock exams gave me the confidence I needed to succeed.
Jason M.
Jason M.Verified Buyer
I was nervous about the ARRT exam, but CertMedbry’s practice questions were so on point that by the time I sat for the exam, I felt totally ready. So grateful for this resource.
Isabella F.
Isabella F.Verified Buyer
I used CertMedbry for my Certified Nurse Educator exam, and it was so helpful. The practice questions were spot-on, and it made studying a lot less stressful.

FAQ

At CertMedbry, our questions are carefully crafted to closely mirror the actual exam. Additionally, we provide instant explanations after each question, offering not only the correct answer but also insights into why the other options are incorrect.
Once your payment is complete, you will have immediate access to all resources, including practice questions, study guides, and detailed explanations for every question.
If you don’t pass your exam after using our services, we will provide you with another round of free access until you pass successfully.
Our platform is compatible with various devices, including mobile phones, iPads, tablets, and laptops, ensuring you can access our resources on any device of your choice.
After purchasing any of our products, you will automatically receive three bonuses, accessible via your account page. These bonuses are designed to enrich your learning experience and add extra value to your selected product.
Our practice questions are designed to closely resemble the format and difficulty of the real exam. However, we respect the official organization’s copyright, so we do not replicate the exact questions. Any provider that claims you can pass simply by memorizing a question bank is not providing a sustainable solution for long-term success.
Absolutely! After your payment is processed, we will promptly send you an official invoice via email. It will include details such as your email address, the product purchased, the cost, and the date of purchase. We aim to ensure you have a clear record of your transaction without any delays.

Become A Medical Professional Today

Pass your medical exams with confidence